GE SR750/760 Relay Tutorials - Part 6: Creating Phase Overcurrent Protection Element Blocks and Parameters

In this tutorial, will show how to create multiple blocks and parameters, copying blocks and parameters, linking parameters to another parameters using conditional formula like iif() , inserting overcurrent test module in the test document (OCC). Welcome to the sixth part of GE SR750/760 Relay Tutorial series. If you haven't seen the previous tutorials, click the link below: Part 5: Link XRIO Parameters Into RIO Device Function In The Test Object GE SR750/760 Relay Tutorials Open the test document that been created from the previous tutorial ( Part 3 ). When the Omicron Control Center document is open, select the Hardware Configuration then go to Insert tab in the ribbon menu. In the Insert tab, click the Group button to insert a new folder group under the Hardware Configuration. Right click on the new group and select properties. In the properties dialog box, set the title to Phase Current. Select the Phase Current group and go to Insert tab then click Group button. Right click o...

GE SR750/760 Relay Tutorials - Part 5: Link XRIO Parameters Into RIO Device Function In The Test Object

Welcome to the fifth part of GE SR750/760 Relay Tutorial series. In this tutorial, I will show you how to link XRIO parameters into RIO Device Function, writing formula in the script function editor, I will show you how to make this test plan/routine flexible during relay testing and also, other stuff. Device function block contains general information and settings such as: the test object's name or description and its manufacturer * the test object's device type and address * the test object's serial or model number * additional information to identify the test object * power system nominal values * residual factors * overload detection sensitivity * limits * and others *  * Reference from Omicron Test Universe help manual If you haven't seen the previous tutorials, click the link below: GE SR750/760 Relay Tutorials - Part 4: Add XRIO Parameters And Link Them To Other Parameters In The Test Object GE SR750/760 Relay Tutorials Open the test...

GE SR750/760 Relay Tutorials - Part 4: Add XRIO Parameters And Link Them To Other Parameters In The Test Object

Welcome to the fourth part of GE SR750/760 Relay Tutorial series. In this tutorial, I will show you how to create Real, Enumeration, Boolean and Integer parameters and link them to other parameters. If you haven't seen the previous tutorials, click the link below: Part 3: Setup Omicron Control Center (OCC) for Testing GE SR750/760 Relay Tutorials Now, open the test document that created from the previous tutorial ( Part 3 ). Add new blocks and parameters Open the Test Object in the test document, expand the relay parameters node and right click on to system setup then click Add Block and rename it to Sensing the same in the EnerVista 750/760 Setup. Now, add four parameters for current sensing. One string data type and three real data type. Rename those as per the image below. Right click on to current sensing parameter or double click on it to open the Parameter Details dialog box to change the name, ID, formula and other settings. See the parameter details in the table below. Onc...